Supermicro SYS-5016I-MR Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Server Barebones Supermicro SYS-5016I-MR herunter. Supermicro SYS-5016I-MR server barebone Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SUPER
SuperServer 5016I-MR
S
uperServer 5016I-MRF
®
USER’S MANUAL
Revision 1.0
Seitenansicht 0
1 2 3 4 5 6 ... 99 100

Inhaltsverzeichnis

Seite 1 - SUPER

SUPERSuperServer 5016I-MRSuperServer 5016I-MRF®USER’S MANUALRevision 1.0

Seite 2 - Release Date: October 7, 2009

NotesSUPERSERVER 5016I-MR/5016I-MRF User's Manual

Seite 3 - Manual Organization

C-4SUPERSERVER 5016I-MR/5016I-MRF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in

Seite 4

Chapter 1 Introduction1-1 OverviewThe SuperServer 5016I-MR/5016I-MRF is 1U server comprised of two main subsys-tems: the SC512-200 mini 1U chassis and

Seite 5

1-2SUPERSERVER 5016I-MR/5016I-MRF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5016I-MR/5016I-MRF lies the X8SIL/X8SIL-F,

Seite 6 - Table of Contents

1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe SC512-200 is a mini 1U rackmount server platform confi guration. The following is a general o

Seite 7 - Chapter 4 System Safety

1-4SUPERSERVER 5016I-MR/5016I-MRF User's ManualFigure 1-1. Intel 3400 Chipset: System Block Diagram Note: This is a general block diagram. Please

Seite 8

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40

Seite 9 - Chapter 7 BIOS

1-6SUPERSERVER 5016I-MR/5016I-MRF User's ManualNotes

Seite 10

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5016I-

Seite 11 - Introduction

2-2SUPERSERVER 5016I-MR/5016I-MRF User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipment

Seite 12 - 1-2 Motherboard Features

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Seite 13 - 1-3 Server Chassis Features

Manual Revision 1.0 Release Date: October 7, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurat

Seite 14 - System Block Diagram

2-4SUPERSERVER 5016I-MR/5016I-MRF User's Manual2-4 Installing the System into a Rack(Rack hardware optional)This section provides information on

Seite 15 - 1-4 Contacting Supermicro

Chapter 2: Server Installation2-5Installing the Chassis RailsThe two rail sections must be detached from each other prior to installation: depress the

Seite 16

2-6SUPERSERVER 5016I-MR/5016I-MRF User's ManualFigure 2-3. Installing the Server into a Rack: BasicInstalling the Server into the RackYou should

Seite 17 - Server Installation

Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Rack: w/ Rackmount KitInstalling the Server into a Telco RackTo install the

Seite 18 - Warnings and Precautions!

2-8SUPERSERVER 5016I-MR/5016I-MRF User's ManualFigure 2-5. Installing the Server into a Telco Rack: Basic2-5 Checking the Motherboard SetupAfter

Seite 19 - Rack Mounting Considerations

Chapter 2: Server Installation2-9Figure 2-6. Installing the Server into a Telco Rack: w/ Rackmount KitNext, depress the two buttons on the top of the

Seite 20 - Installing with Rackmount Kit

2-10SUPERSERVER 5016I-MR/5016I-MRF User's ManualFigure 2-7. Accessing the Inside of the SystemMake sure all power and data cables are properly co

Seite 21 - Installing the Rack Rails

Chapter 2: Server Installation2-11Checking the Airfl owAirfl ow is provided by one 10-cm input fan. The system component layout 1. was carefully designe

Seite 22

2-12SUPERSERVER 5016I-MR/5016I-MRF User's ManualNotes

Seite 23

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel to keep you constantly informed of the

Seite 24

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Seite 25

3-2SUPERSERVER 5016I-MR/5016I-MRF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC512-200 chassis has fi ve L

Seite 26

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Seite 27

3-4SUPERSERVER 5016I-MR/5016I-MRF User's ManualNotes

Seite 28

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions shall be followed to protect

Seite 29 - System Interface

4-2SUPERSERVER 5016I-MR/5016I-MRF User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around th

Seite 30 - 3-3 Control Panel LEDs

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into

Seite 31 - Chapter 3: System Interface

4-4SUPERSERVER 5016I-MR/5016I-MRF User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the

Seite 32

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install the X8SIL motherboard in

Seite 33 - System Safety

5-2SUPERSERVER 5016I-MR/5016I-MRF User's Manual5-2 Motherboard InstallationThis section explains the fi rst step of physically mounting the X8SIL

Seite 34

Chapter 5: Advanced Motherboard Setup5-3cables (with their locations noted) should be connected. (See the layout on page 5-9 for connector locations.)

Seite 35 - 4-3 ESD Precautions

ivChapter 5: Advanced Motherboard SetupChapter 5 provides detailed information on the X8SIL/X8SIL-F motherboard, in-cluding the locations and functio

Seite 36 - BATTERY HOLDER

5-4SUPERSERVER 5016I-MR/5016I-MRF User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figur

Seite 37 - Advanced Motherboard Setup

Chapter 5: Advanced Motherboard Setup5-5Installing the LGA1156 Processor Press the load lever to release the load plate, which covers the CPU socket,

Seite 38 - 5-3 Connecting Cables

5-6SUPERSERVER 5016I-MR/5016I-MRF User's ManualAlign the CPU key that is the semi-circle cutouts against the socket keys. 4. Once aligned, carefu

Seite 39 - Connecting the Control Panel

Chapter 5: Advanced Motherboard Setup5-7Installing a Passive CPU HeatsinkDo not apply any thermal grease to the heatsink or the CPU die -- the re-1. q

Seite 40 - 5-4 I/O Ports

5-8SUPERSERVER 5016I-MR/5016I-MRF User's ManualRemoving the HeatsinkWarning: We do not recommend removing the CPU or the heatsink. How-ever, if y

Seite 41

Chapter 5: Advanced Motherboard Setup5-95-6 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONExercise extrem

Seite 42

5-10SUPERSERVER 5016I-MR/5016I-MRF User's ManualTable 2 - DDR3 ECC Registered (RDIMM) Memory SupportRDIMM 1Gb (x8 DRAM) 2Gb (x8 DRAM)Single Rank

Seite 43

Chapter 5: Advanced Motherboard Setup5-11Figure 5-5. DIMM InstallationNote: Due to memory allocation to system devices, the amount of memory that rema

Seite 44 - Removing the Heatsink

5-12SUPERSERVER 5016I-MR/5016I-MRF User's Manual5-7 Installing PCI Add-On CardsThe SC512-200 chassis uses a riser card to accommodate one add-on

Seite 45 - 5-6 Installing Memory

Chapter 5: Advanced Motherboard Setup5-13Figure 5-6. X8SIL Layout5-8 Motherboard Details1MAC CODEJPI2CJF1JPW1U26J8J6J5J141J13U61T-SGPIO1T-SGPIO2J24JLA

Seite 47

5-14SUPERSERVER 5016I-MR/5016I-MRF User's ManualX8SIL/X8SIL-F JumpersNumber Jumper Description Default38 JPUSB1 BP USB0/1 Wake-up Pins 1-2 (Enabl

Seite 48

Chapter 5: Advanced Motherboard Setup5-155-9 Connector Defi nitions ATX Power 24-pin ConnectorPin Defi nitions (JPW1)Pin# Defi nition Pin #

Seite 49 - 5-8 Motherboard Details

5-16SUPERSERVER 5016I-MR/5016I-MRF User's ManualHDD LEDThe HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display HD

Seite 50

Chapter 5: Advanced Motherboard Setup5-17Fan HeadersThe X8SIL has fi ve fan headers, all of which are 4-pin fans. However, pins 1-3 of the fan headers

Seite 51 - 5-9 Connector Defi nitions

5-18SUPERSERVER 5016I-MR/5016I-MRF User's ManualLAN1/LAN2 (Ethernet Ports)Two Ethernet ports are located on the I/O backplane. These ports accept

Seite 52

Chapter 5: Advanced Motherboard Setup5-19NC = No ConnectionPower Supply I2C ConnectorThe Power Supply (I2C) connector is located at SMB_PS1 and is use

Seite 53

5-20SUPERSERVER 5016I-MR/5016I-MRF User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers ca

Seite 54

Chapter 5: Advanced Motherboard Setup5-21LAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the LAN1 and LAN2 Eth

Seite 55

5-22SUPERSERVER 5016I-MR/5016I-MRF User's Manual5-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located on the I/O backplane) have two LEDs

Seite 56 - 5-10 Jumper Settings

Chapter 5: Advanced Motherboard Setup5-235-12 SATA and Floppy Drive ConnectionsSATA PortPin Defi nitions(I-SATA0 ~ I-SATA3)Pin # Defi nitio

Seite 57

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Seite 58 - 5-11 Onboard Indicators

5-24SUPERSERVER 5016I-MR/5016I-MRF User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the opera

Seite 59 - (I-SATA0 ~ I-SATA3)

Chapter 5: Advanced Motherboard Setup5-25Supero Doctor IIIThe Supero Doctor III program is a Web-based management tool that supports remote management

Seite 60 - 5-13 Installing Software

5-26SUPERSERVER 5016I-MR/5016I-MRF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.c

Seite 61 - Supero Doctor III

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Seite 62

6-2SUPERSERVER 5016I-MR/5016I-MRF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chas

Seite 63 - Advanced Chassis Setup

Chapter 6: Advanced Chassis Setup6-36-3 System FansOne 10-cm blower fan provides the cooling for the SuperServer 5016I-MR/5016I-MRF. The chassis inclu

Seite 64 - 6-2 Control Panel

6-4SUPERSERVER 5016I-MR/5016I-MRF User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysFor installing or removing a DVD-ROM or

Seite 65 - 6-3 System Fans

Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Removing the SATA/DVD-ROM DriveAttach the side rails and backplane PCB to the DVD-ROM drive (see Figu

Seite 66 - Accessing the Drive Bays

6-6SUPERSERVER 5016I-MR/5016I-MRF User's Manual6-5 Power SupplyThe SuperServer 5016I-MR/5016I-MRF has a single 200 watt power supply. This power

Seite 67

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8SIL/X8SIL-F. The AMI ROM BIOS is stored i

Seite 68 - 6-5 Power Supply

viiTable of Contents2-5 Checking the Motherboard Setup ... 2-82-6 Checking the Drive

Seite 69 - Chapter 7

7-2SUPERSERVER 5016I-MR/5016I-MRF User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the

Seite 70 - 7-2 Main Setup

Chapter 7: BIOS7-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system time

Seite 71

7-4SUPERSERVER 5016I-MR/5016I-MRF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to

Seite 72 - XBOOT Feature

Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The opti

Seite 73 - Processor & Clock Options

7-6SUPERSERVER 5016I-MR/5016I-MRF User's Manualthe components whenever needed. Select Disabled to enhance system stability. The options are Disab

Seite 74

Chapter 7: BIOS7-7Intel® Turbo Boost Technology (Available if Intel® EIST technology is Enabled)This feature allows processor cores to run faster than

Seite 75 - Advanced Chipset Control

7-8SUPERSERVER 5016I-MR/5016I-MRF User's ManualActive State Power ManagementSelect Enabled to start Active-State Power Management for signal tran

Seite 76 - SATA / Floppy Confi guration

Chapter 7: BIOS7-9SATA#2 Confi guration (Available if IDE is enabled under "Confi gure SATA#1 as" above)Selecting Enhanced will set SATA#2 to

Seite 77

7-10SUPERSERVER 5016I-MR/5016I-MRF User's ManualSelect Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE

Seite 78

Chapter 7: BIOS7-11Select UDMA4 to allow the BIOS to use Ultra DMA mode 4 . It has a data transfer rate of 100 MBs. The options are Auto, SWDMAn, MWDM

Seite 79 - XPCI/PnP Confi guration

viiiMain ATX Power Supply Connector ... 5-15Processor Power Connector ...

Seite 80

7-12SUPERSERVER 5016I-MR/5016I-MRF User's ManualPCI Slots 5, 6, 7 & PCI Slot 4 OPROMUse this feature to enable or disable PCI slot Option ROM

Seite 81 - XRemote Access Confi guration

Chapter 7: BIOS7-13XRemote Access Confi guration Remote Access This allows the user to enable the Remote Access feature. The options are Dis-abled and

Seite 82 - Hardware Health Confi guration

7-14SUPERSERVER 5016I-MR/5016I-MRF User's ManualXHardware Health Confi gurationThis feature allows the user to monitor Hardware Health of the syst

Seite 83

Chapter 7: BIOS7-15User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.High – T

Seite 84 - XACPI Confi guration

7-16SUPERSERVER 5016I-MR/5016I-MRF User's ManualCPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workst

Seite 85

Chapter 7: BIOS7-17ACPI Version FeaturesThe options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanatio

Seite 86 - XEvent Log Confi guration

7-18SUPERSERVER 5016I-MR/5016I-MRF User's ManualIP Address - Enter the IP address for this machine. This should be in decimal and in dotted quad

Seite 87

Chapter 7: BIOS7-19on the system. The options are Enabled and Disabled. When enabled the following information are displayed along with their status.:

Seite 88 - 7-4 Security Settings

7-20SUPERSERVER 5016I-MR/5016I-MRF User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both pass

Seite 89 - 7-5 Boot Settings

Chapter 7: BIOS7-21Use this feature to confi gure Boot Settings:XBoot Device PriorityThis feature allows the user to specify the sequence of priority f

Seite 90 - 7-6 Exit Options

Chapter 6 Advanced Chassis Setup6-1 Static-Sensitive Devices ... 6-1Pre

Seite 91

7-22SUPERSERVER 5016I-MR/5016I-MRF User's ManualSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Sa

Seite 92

Chapter 7: BIOS7-23Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration

Seite 93 - POST Error Beep Codes

7-24SUPERSERVER 5016I-MR/5016I-MRF User's ManualNotes

Seite 94

Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesThis section lists POST (Power On Self Test) error beep codes for the AMI BIOS. PO

Seite 95 - Installing Windows

A-2SUPERSERVER 5016I-MR/5016I-MRF User's ManualNotes

Seite 96

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South

Seite 97 - System Specifi cations

B-2SUPERSERVER 5016I-MR/5016I-MRF User's ManualB-2 Installing Windows to a Non-RAID SystemInsert Microsoft's Windows OS Setup CD in the CD-

Seite 98

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors One Intel® 3400 series processor in an LGA1156 socket Note:

Seite 99

C-2SUPERSERVER 5016I-MR/5016I-MRF User's ManualWeight Net (Gross): 17 lbs. (7.7 kg.)System Cooling One (1) 10-cm ball bearing blowe

Seite 100

C-3Appendix C: System Specifi cationsNotes