Inhaltsverzeichnis

Seite 1 - SUPER

H8QG6-F H8QGi-F USER’S MANUALRevision 1.0d® SUPER

Seite 2

1-2H8QG6/i-F Serverboard User’s Manual1-2 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.

Seite 3 - Manual Organization

Chapter 1: Introduction1-3Figure 1-1. H8QG6-F Image

Seite 4

1-4H8QG6/i-F Serverboard User’s ManualNotes:Jumpers not indicated are for test purposes only.Not all ports, jumpers or LED Indicators are available on

Seite 5 - Table of Contents

Chapter 1: Introduction1-5H8QG6/i-F Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JI2C1/JI2C2 I2C to PCI-E Slot En

Seite 6

1-6H8QG6/i-F Serverboard User’s ManualConnector DescriptionCOM1/COM2 COM1 Serial Port/HeaderFAN 1-9 Chassis/CPU Fan Headers IPMI LAN Dedicated IPMI LA

Seite 7 - Chapter 4 BIOS

Chapter 1: Introduction1-7Motherboard FeaturesCPUQuad AMD Opteron 6100 series (Socket G34 type) processors• Note: You must install at least two proces

Seite 8

1-8H8QG6/i-F Serverboard User’s ManualACPI FeaturesMicrosoft OnNow• Slow blinking LED for suspend state indicator• BIOS support for USB keyboard• Wake

Seite 9 - Introduction

Chapter 1: Introduction1-9G34-SOCKET #38x DIMM8x DIMMFWHKeyboard/MouseLPC SIOW83527DHG-PG34-SOCKET #2VRMG34-SOCKET #4PCIE (X16)H/W_MONITORW83795AMDSR5

Seite 10 - 1-2 Contacting Supermicro

1-10H8QG6/i-F Serverboard User’s Manual1-3 Chipset OverviewThe H8QG6/i-F serverboard is based on the AMD SR5690/SR5670/SP5100 chipset. This chipset fu

Seite 11 - Figure 1-1. H8QG6-F Image

Chapter 1: Introduction1-11CPU Overheat/Fan Fail LED and Control This feature is available when the user enables the CPU overheat/Fan Fail warning fun

Seite 12

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Seite 13 - H8QG6/i-F Quick Reference

1-12H8QG6/i-F Serverboard User’s ManualWake-On-LAN (WOL)Wake-On-LAN is defi ned as the ability of a management application to remotely power up a compu

Seite 14 - Connector Description

Chapter 1: Introduction1-13The IRQs, DMAs and I/O space resources of the Super I/O can be fl exibly adjusted to meet ISA PnP requirements, which suppor

Seite 15 - Motherboard Features

1-14H8QG6/i-F Serverboard User’s ManualNotes

Seite 16

Chapter 2: Installation2-1Chapter 2 Installation2-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To preven

Seite 17 - SR5670-S

H8QG6/i-F Serverboard User's Manual2-2!2-2 Processor and Heatsink InstallationExercise extreme caution when handling and installing the processo

Seite 18 - 1-3 Chipset Overview

Chapter 2: Installation2-3Installing the HeatsinksWe recommend the use of active type heatsinks (except for 1U systems). Use any onboard fan header fo

Seite 19

H8QG6/i-F Serverboard User's Manual2-42-3 Mounting the Motherboard into a ChassisAll motherboards have standard mounting holes to fi t different

Seite 20 - 1-7 Super I/O

Chapter 2: Installation2-5Gently press down on the memory module until it snaps into place.3. With four CPUs installed, repeat step 2 to populate the

Seite 21

H8QG6/i-F Serverboard User's Manual2-6Memory Population for Optimal Performance-For a Motherboard with One CPU (CPU1) Installed# DIMMS CPU Channe

Seite 22

Chapter 2: Installation2-7Note 2: Due to memory allocation to system devices, the amount of memory that remains available for operational use will be

Seite 23 - Installation

PrefaceiiiPrefaceAbout This ManualThis manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information fo

Seite 24

H8QG6/i-F Serverboard User's Manual2-82-5 PCI Expansion CardsA riser card is used to support one standard size (full height full length) PCI exp

Seite 25

Chapter 2: Installation2-92-6 I/O Port and Control Panel ConnectionsThe I/O ports are color coded in conformance with the PC99 specifi cation to make

Seite 26 - 2-4 Installing Memory

H8QG6/i-F Serverboard User's Manual2-102-7 Connector Defi nitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU

Seite 27 - Maximum Memory

Chapter 2: Installation2-11Power LED ConnectorThe Power LED connector is on pins 15 and 16 of JF1. See the table on the right for pin defi nitions.Powe

Seite 28

H8QG6/i-F Serverboard User's Manual2-12Universal Serial Bus PortsTwo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mou

Seite 29 - Chapter 2: Installation

Chapter 2: Installation2-13Wake-On-LANThe Wake-On-LAN header is designated JWOL. See the table on the right for pin defi nitions. You must have a LAN c

Seite 30 - 2-5 PCI Expansion Cards

H8QG6/i-F Serverboard User's Manual2-14Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you

Seite 31 - 4. IPMI LAN 9. UID

Chapter 2: Installation2-15UID ButtonPin Defi nitionsPin# Defi nition1 Ground2 Ground3 Button In4 GroundUnit Identifi er ButtonThere is a Unit Identifi

Seite 32 - 2-7 Connector Defi nitions

H8QG6/i-F Serverboard User's Manual2-162-8 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be used t

Seite 33

Chapter 2: Installation2-17VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA.

Seite 34

ivH8QG6/i-F Serverboard User’s ManualNotes

Seite 35

H8QG6/i-F Serverboard User's Manual2-18Backpanel USB Wake-Up Enable (JPUSB1)Jumper SettingsJumper Setting Defi nitionPins 1-2 Enabled (defaul

Seite 36

Chapter 2: Installation2-192-9 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, on

Seite 37 - Pin Defi nitions (JTPM1)

H8QG6/i-F Serverboard User's Manual2-202-10 SAS and SATA Drive ConnectionsSATA PortsThere are no jumpers to confi gure the SATA ports, which are

Seite 38 - 2-8 Jumper Settings

Chapter 2: Installation2-212-11 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and the SATA RAID drivers, i

Seite 39

H8QG6/i-F Serverboard User's Manual2-22Figure 2-4. BIOS Setup ScreenNote: You need to have an external USB fl oppy when building the driver disket

Seite 40 - BMC Jumper Enable (JPB1)

Chapter 2: Installation2-23After exiting the BIOS Setup Utility, the system will reboot. When prompted 4. during the startup, press the <CTRL+A>

Seite 41 - 2-9 Onboard Indicators

H8QG6/i-F Serverboard User's Manual2-24Figure 2-6. Driver/Tool Installation Display Screen2-12 Installing DriversThe CD that came bundled with th

Seite 42

Chapter 2: Installation2-25Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management capability. It

Seite 43 - 2-11 Enabling SATA RAID

H8QG6/i-F Serverboard User's Manual2-26Note: Super Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro

Seite 44

3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If you h

Seite 45

vTable of ContentsChapter 1 Introduction1-1 Overview ...

Seite 46 - 2-12 Installing Drivers

3-2H8QG6/i-F Serverboard User's ManualTurn the power switch on and off to test the system.4. The battery on your motherboard may be old. Check to

Seite 47 - Supero Doctor III

3-3Chapter 3: Troubleshooting3-2 Technical Support ProceduresBefore contacting Technical Support, please take the following steps. Also, note that as

Seite 48

3-4H8QG6/i-F Serverboard User's ManualSelect your motherboard model on the web page and download the corresponding BIOS fi le to your computer. Un

Seite 49 - Troubleshooting

Chapter 4: BIOS4-1Chapter 4 BIOS4-1 IntroductionThis chapter describes the AMIBIOS™ Setup utility for the H8QG6/i-F serverboard. The AMI ROM BIOS is s

Seite 50 - Memory Errors

4-2H8QG6/i-F Serverboard User’s Manual4-2 Main MenuWhen you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen.You can always retur

Seite 51 -  System confi guration

Chapter 4: BIOS4-3is detected, at which point you will need to press the F1 button to re-enter the BIOS setup menu. The options are Enabled and Disabl

Seite 52

4-4H8QG6/i-F Serverboard User’s ManualACPI SRAT TableThis option Enables or Disables the building of the ACPI SRAT Table.CPU DownCore ModeThis option

Seite 53 - Chapter 4

Chapter 4: BIOS4-5 ECC Confi gurationECC ModeThis submenu sets the level of ECC protection. Options include Disabled, Basic, Good, Super, Max and User

Seite 54 - 4-3 Advanced Settings Menu

4-6H8QG6/i-F Serverboard User’s ManualLegacy USB SupportSelect "Enabled" to enable the support for USB Legacy. Disable Legacy support if the

Seite 55

Chapter 4: BIOS4-7Use this value if the IDE disk drive support cannot be determined. Select 0 to allow BIOS to use PIO mode 0, which has a data transf

Seite 56 -  Memory Confi guration

viSGPIO ... 13SMBus Header ...

Seite 57 -  DRAM Timing Confi guration

4-8H8QG6/i-F Serverboard User’s Manual PCI/PNP Confi gurationClear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug &

Seite 58 -  IDE/SATA Confi guration

Chapter 4: BIOS4-9Serial 2 AddressThis option specifi es the base I/O port address and Interrupt Request address of serial port 2. Select "Disable

Seite 59

4-10H8QG6/i-F Serverboard User’s ManualSredir Memory Display Delay Use this setting to set the delay in seconds to display memory information. Options

Seite 60 -  SuperI/O Confi guration

Chapter 4: BIOS4-11ACPI Version FeaturesUse this setting the determine which ACPI version to use. Options are ACPI v1.0, ACPI v2.0 and ACPI v3.0.ACPI

Seite 61 -  Remote Access Confi guration

4-12H8QG6/i-F Serverboard User’s Manual MAC Address In the fi eld provided here enter the MAC address in the hex form of xx.xx.xx.xx.xx.xx with xx in

Seite 62 -  ACPI Confi guration

Chapter 4: BIOS4-134-6 Security Settings MenuAMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password m

Seite 63 - IP Address

4-14H8QG6/i-F Serverboard User’s Manual CD/DVD DrivesThis feature allows you to specify the boot sequence from the list of available CD/DVD drives. A

Seite 64 -  Event Log Confi guration

Chapter 4: BIOS4-15Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then Select &quo

Seite 65 - 4-5 Boot Settings Menu

4-16H8QG6/i-F Serverboard User’s ManualNotes

Seite 66 - 4-8 Exit Menu

Appendix A BIOS Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occu

Seite 67

Table of ContentsviiUsing the Adaptec RAID Utility ... 23Installing the RAID Driv

Seite 68

A-2H8QG6/i-F Serverboard User’s ManualNotes

Seite 69 - BIOS Error Beep Codes

B-1Appendix B: BIOS POST Checkpoint CodesAppendix B BIOS POST Checkpoint CodesWhen AMIBIOS performs the Power On Self Test, it writes checkpoint codes

Seite 70

B-2H8DGU(-F) Serverboard User’s ManualB-2 Bootblock Recovery CodesThe bootblock recovery checkpoint codes are listed in order of execution:Checkpoint

Seite 71 - BIOS POST Checkpoint Codes

B-3Appendix B: BIOS POST Checkpoint CodesB-3 Uncompressed Initialization CodesThe following runtime checkpoint codes are listed in order of execution

Seite 72 - B-2 Bootblock Recovery Codes

B-4H8DGU(-F) Serverboard User’s ManualCheckpoint Code Description2Eh Completed post-video ROM test processing. If the EGA/VGA controller is not found,

Seite 73 - Checkpoint Code Description

B-5Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description54h Shutdown was successful. The CPU is in real mode. Disabling the Gate A20 line,

Seite 74

B-6H8DGU(-F) Serverboard User’s ManualCheckpoint Code Description99h Any initialization required after the option ROM test has completed. Confi guring

Seite 75

NotesviiiH8QG6/i-F Serverboard User’s Manual

Seite 76

Chapter 1: Introduction1-1Chapter 1 Introduction1-1 OverviewChecklistCongratulations on purchasing your computer motherboard from an acknowledged lead