H8QG6-F H8QGi-F USER’S MANUALRevision 1.0d® SUPER
1-2H8QG6/i-F Serverboard User’s Manual1-2 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.
Chapter 1: Introduction1-3Figure 1-1. H8QG6-F Image
1-4H8QG6/i-F Serverboard User’s ManualNotes:Jumpers not indicated are for test purposes only.Not all ports, jumpers or LED Indicators are available on
Chapter 1: Introduction1-5H8QG6/i-F Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JI2C1/JI2C2 I2C to PCI-E Slot En
1-6H8QG6/i-F Serverboard User’s ManualConnector DescriptionCOM1/COM2 COM1 Serial Port/HeaderFAN 1-9 Chassis/CPU Fan Headers IPMI LAN Dedicated IPMI LA
Chapter 1: Introduction1-7Motherboard FeaturesCPUQuad AMD Opteron 6100 series (Socket G34 type) processors• Note: You must install at least two proces
1-8H8QG6/i-F Serverboard User’s ManualACPI FeaturesMicrosoft OnNow• Slow blinking LED for suspend state indicator• BIOS support for USB keyboard• Wake
Chapter 1: Introduction1-9G34-SOCKET #38x DIMM8x DIMMFWHKeyboard/MouseLPC SIOW83527DHG-PG34-SOCKET #2VRMG34-SOCKET #4PCIE (X16)H/W_MONITORW83795AMDSR5
1-10H8QG6/i-F Serverboard User’s Manual1-3 Chipset OverviewThe H8QG6/i-F serverboard is based on the AMD SR5690/SR5670/SP5100 chipset. This chipset fu
Chapter 1: Introduction1-11CPU Overheat/Fan Fail LED and Control This feature is available when the user enables the CPU overheat/Fan Fail warning fun
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
1-12H8QG6/i-F Serverboard User’s ManualWake-On-LAN (WOL)Wake-On-LAN is defi ned as the ability of a management application to remotely power up a compu
Chapter 1: Introduction1-13The IRQs, DMAs and I/O space resources of the Super I/O can be fl exibly adjusted to meet ISA PnP requirements, which suppor
1-14H8QG6/i-F Serverboard User’s ManualNotes
Chapter 2: Installation2-1Chapter 2 Installation2-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To preven
H8QG6/i-F Serverboard User's Manual2-2!2-2 Processor and Heatsink InstallationExercise extreme caution when handling and installing the processo
Chapter 2: Installation2-3Installing the HeatsinksWe recommend the use of active type heatsinks (except for 1U systems). Use any onboard fan header fo
H8QG6/i-F Serverboard User's Manual2-42-3 Mounting the Motherboard into a ChassisAll motherboards have standard mounting holes to fi t different
Chapter 2: Installation2-5Gently press down on the memory module until it snaps into place.3. With four CPUs installed, repeat step 2 to populate the
H8QG6/i-F Serverboard User's Manual2-6Memory Population for Optimal Performance-For a Motherboard with One CPU (CPU1) Installed# DIMMS CPU Channe
Chapter 2: Installation2-7Note 2: Due to memory allocation to system devices, the amount of memory that remains available for operational use will be
PrefaceiiiPrefaceAbout This ManualThis manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information fo
H8QG6/i-F Serverboard User's Manual2-82-5 PCI Expansion CardsA riser card is used to support one standard size (full height full length) PCI exp
Chapter 2: Installation2-92-6 I/O Port and Control Panel ConnectionsThe I/O ports are color coded in conformance with the PC99 specifi cation to make
H8QG6/i-F Serverboard User's Manual2-102-7 Connector Defi nitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU
Chapter 2: Installation2-11Power LED ConnectorThe Power LED connector is on pins 15 and 16 of JF1. See the table on the right for pin defi nitions.Powe
H8QG6/i-F Serverboard User's Manual2-12Universal Serial Bus PortsTwo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mou
Chapter 2: Installation2-13Wake-On-LANThe Wake-On-LAN header is designated JWOL. See the table on the right for pin defi nitions. You must have a LAN c
H8QG6/i-F Serverboard User's Manual2-14Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you
Chapter 2: Installation2-15UID ButtonPin Defi nitionsPin# Defi nition1 Ground2 Ground3 Button In4 GroundUnit Identifi er ButtonThere is a Unit Identifi
H8QG6/i-F Serverboard User's Manual2-162-8 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be used t
Chapter 2: Installation2-17VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA.
ivH8QG6/i-F Serverboard User’s ManualNotes
H8QG6/i-F Serverboard User's Manual2-18Backpanel USB Wake-Up Enable (JPUSB1)Jumper SettingsJumper Setting Defi nitionPins 1-2 Enabled (defaul
Chapter 2: Installation2-192-9 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, on
H8QG6/i-F Serverboard User's Manual2-202-10 SAS and SATA Drive ConnectionsSATA PortsThere are no jumpers to confi gure the SATA ports, which are
Chapter 2: Installation2-212-11 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and the SATA RAID drivers, i
H8QG6/i-F Serverboard User's Manual2-22Figure 2-4. BIOS Setup ScreenNote: You need to have an external USB fl oppy when building the driver disket
Chapter 2: Installation2-23After exiting the BIOS Setup Utility, the system will reboot. When prompted 4. during the startup, press the <CTRL+A>
H8QG6/i-F Serverboard User's Manual2-24Figure 2-6. Driver/Tool Installation Display Screen2-12 Installing DriversThe CD that came bundled with th
Chapter 2: Installation2-25Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management capability. It
H8QG6/i-F Serverboard User's Manual2-26Note: Super Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro
3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If you h
vTable of ContentsChapter 1 Introduction1-1 Overview ...
3-2H8QG6/i-F Serverboard User's ManualTurn the power switch on and off to test the system.4. The battery on your motherboard may be old. Check to
3-3Chapter 3: Troubleshooting3-2 Technical Support ProceduresBefore contacting Technical Support, please take the following steps. Also, note that as
3-4H8QG6/i-F Serverboard User's ManualSelect your motherboard model on the web page and download the corresponding BIOS fi le to your computer. Un
Chapter 4: BIOS4-1Chapter 4 BIOS4-1 IntroductionThis chapter describes the AMIBIOS™ Setup utility for the H8QG6/i-F serverboard. The AMI ROM BIOS is s
4-2H8QG6/i-F Serverboard User’s Manual4-2 Main MenuWhen you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen.You can always retur
Chapter 4: BIOS4-3is detected, at which point you will need to press the F1 button to re-enter the BIOS setup menu. The options are Enabled and Disabl
4-4H8QG6/i-F Serverboard User’s ManualACPI SRAT TableThis option Enables or Disables the building of the ACPI SRAT Table.CPU DownCore ModeThis option
Chapter 4: BIOS4-5 ECC Confi gurationECC ModeThis submenu sets the level of ECC protection. Options include Disabled, Basic, Good, Super, Max and User
4-6H8QG6/i-F Serverboard User’s ManualLegacy USB SupportSelect "Enabled" to enable the support for USB Legacy. Disable Legacy support if the
Chapter 4: BIOS4-7Use this value if the IDE disk drive support cannot be determined. Select 0 to allow BIOS to use PIO mode 0, which has a data transf
viSGPIO ... 13SMBus Header ...
4-8H8QG6/i-F Serverboard User’s Manual PCI/PNP Confi gurationClear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug &
Chapter 4: BIOS4-9Serial 2 AddressThis option specifi es the base I/O port address and Interrupt Request address of serial port 2. Select "Disable
4-10H8QG6/i-F Serverboard User’s ManualSredir Memory Display Delay Use this setting to set the delay in seconds to display memory information. Options
Chapter 4: BIOS4-11ACPI Version FeaturesUse this setting the determine which ACPI version to use. Options are ACPI v1.0, ACPI v2.0 and ACPI v3.0.ACPI
4-12H8QG6/i-F Serverboard User’s Manual MAC Address In the fi eld provided here enter the MAC address in the hex form of xx.xx.xx.xx.xx.xx with xx in
Chapter 4: BIOS4-134-6 Security Settings MenuAMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password m
4-14H8QG6/i-F Serverboard User’s Manual CD/DVD DrivesThis feature allows you to specify the boot sequence from the list of available CD/DVD drives. A
Chapter 4: BIOS4-15Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then Select &quo
4-16H8QG6/i-F Serverboard User’s ManualNotes
Appendix A BIOS Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occu
Table of ContentsviiUsing the Adaptec RAID Utility ... 23Installing the RAID Driv
A-2H8QG6/i-F Serverboard User’s ManualNotes
B-1Appendix B: BIOS POST Checkpoint CodesAppendix B BIOS POST Checkpoint CodesWhen AMIBIOS performs the Power On Self Test, it writes checkpoint codes
B-2H8DGU(-F) Serverboard User’s ManualB-2 Bootblock Recovery CodesThe bootblock recovery checkpoint codes are listed in order of execution:Checkpoint
B-3Appendix B: BIOS POST Checkpoint CodesB-3 Uncompressed Initialization CodesThe following runtime checkpoint codes are listed in order of execution
B-4H8DGU(-F) Serverboard User’s ManualCheckpoint Code Description2Eh Completed post-video ROM test processing. If the EGA/VGA controller is not found,
B-5Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description54h Shutdown was successful. The CPU is in real mode. Disabling the Gate A20 line,
B-6H8DGU(-F) Serverboard User’s ManualCheckpoint Code Description99h Any initialization required after the option ROM test has completed. Confi guring
NotesviiiH8QG6/i-F Serverboard User’s Manual
Chapter 1: Introduction1-1Chapter 1 Introduction1-1 OverviewChecklistCongratulations on purchasing your computer motherboard from an acknowledged lead