Supermicro 5016I-T Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Server Barebones Supermicro 5016I-T herunter. Supermicro SYS-5016I-TF server barebone Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 98
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SUPER
SuperServer 5016I-T
SuperServer 5016I-TF
®
USER’S MANUAL
Revision 1.0
Seitenansicht 0
1 2 3 4 5 6 ... 97 98

Inhaltsverzeichnis

Seite 1 - SUPER

SUPERSuperServer 5016I-TSuperServer 5016I-TF®USER’S MANUALRevision 1.0

Seite 2 - Release Date: October 6, 2009

NotesSUPERSERVER 5016I-T/5016I-TF User's Manual

Seite 3 - Manual Organization

Chapter 1 Introduction1-1 OverviewThe SuperServer 5016I-T/5016I-TF is a high-end server comprised of two main sub-systems: the SC811T-280 1U chassis a

Seite 4

1-2SUPERSERVER 5016I-T/5016I-TF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5016I-T/5016I-TF lies the X8SIL/X8SIL-F, a s

Seite 5

1-3Chapter 1: Introduction1-3 Chassis FeaturesSystem PowerThe SC811T-280 chassis includes a single 280W power supply. Serial ATA SubsystemThe SC811T-

Seite 6 - Table of Contents

1-4SUPERSERVER 5016I-T/5016I-TF User's ManualFigure 1-1. Intel 3400/3420 Chipset: System Block Diagram Note: This is a general block diagram. Ple

Seite 7 - Chapter 4 System Safety

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40

Seite 8

1-6SUPERSERVER 5016I-T/5016I-TF User's ManualNotes

Seite 9 - Chapter 7 BIOS

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5016I-

Seite 10

2-2SUPERSERVER 5016I-T/5016I-TF User's ManualChoosing a Setup LocationLeave enough clearance in front of the rack to enable you to open the front

Seite 11 - Introduction

Chapter 2: Server Installation2-3Use a regulating uninterruptible power supply (UPS) to protect the server from • power surges, voltage spikes and to

Seite 12 - 1-2 Motherboard Features

Manual Revision 1.0 Release Date: October 6, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurat

Seite 13 - 1-3 Chassis Features

2-4SUPERSERVER 5016I-T/5016I-TF User's ManualFigure 2-1. Identifying the Sections of the Rack RailsAB2-4 Installing the System into a RackThis

Seite 14 - System Block Diagram

Chapter 2: Server Installation2-5Installing the Chassis RailsPosition the fixed chassis rail sections you just removed along the side of the chassis m

Seite 15 - 1-4 Contacting Supermicro

2-6SUPERSERVER 5016I-T/5016I-TF User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have

Seite 16

Chapter 2: Server Installation2-7Installing the Server into a Telco RackIf you are installing the server into a Telco type rack, follow the directions

Seite 17 - Server Installation

2-8SUPERSERVER 5016I-T/5016I-TF User's Manual2-5 Checking the Serverboard SetupAfter you install the 5016I-T/5016I-TF in the rack, you will need

Seite 18 - Warnings and Precautions!

Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the System

Seite 19 - Rack Mounting Considerations

2-10SUPERSERVER 5016I-T/5016I-TF User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the

Seite 20

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the Serial ATA dr

Seite 21 - Installing the Rack Rails

3-2SUPERSERVER 5016I-T/5016I-TF User's ManualOverheat/Fan FailWhen this LED fl ashes, it indicates a fan failure. When on continuously it indicate

Seite 22

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Seite 23

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It pro-vides information for the installation a

Seite 24

3-4SUPERSERVER 5016I-T/5016I-TF User's ManualNotes

Seite 25

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions shall be followed to protect

Seite 26

4-2SUPERSERVER 5016I-T/5016I-TF User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the

Seite 27 - System Interface

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into

Seite 28 - Overheat/Fan Fail

4-4SUPERSERVER 5016I-T/5016I-TF User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 50

Seite 29

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install the X8SIL/X8SIL-F mother

Seite 30

5-2SUPERSERVER 5016I-T/5016I-TF User's Manual5-2 Motherboard InstallationThis section explains the fi rst step of physically mounting the X8SIL/X8

Seite 31 - System Safety

Chapter 5: Advanced Motherboard Setup5-3cables (with their locations noted) should be connected. (See the layout on page 5-9 for connector locations.)

Seite 32

5-4SUPERSERVER 5016I-T/5016I-TF User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure

Seite 33 - 4-3 ESD Precautions

Chapter 5: Advanced Motherboard Setup5-5Installing the LGA1156 Processor Press the load lever to release the load plate, which covers the CPU socket,

Seite 34 - BATTERY HOLDER

ivto this chapter when adding or removing processors or main memory and when reconfi guring the motherboard.Chapter 6: Advanced Chassis SetupRefer to

Seite 35 - Advanced Motherboard Setup

5-6SUPERSERVER 5016I-T/5016I-TF User's ManualAlign the CPU key that is the semi-circle cutouts against the socket keys. 4. Once aligned, carefull

Seite 36 - 5-3 Connecting Cables

Chapter 5: Advanced Motherboard Setup5-7Installing a Passive CPU HeatsinkDo not apply any thermal grease to the heatsink or the CPU die -- the re-1. q

Seite 37 - Connecting the Control Panel

5-8SUPERSERVER 5016I-T/5016I-TF User's ManualRemoving the HeatsinkWarning: We do not recommend removing the CPU or the heatsink. How-ever, if you

Seite 38 - 5-4 I/O Ports

Chapter 5: Advanced Motherboard Setup5-95-6 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONExercise extrem

Seite 39

5-10SUPERSERVER 5016I-T/5016I-TF User's ManualTable 2 - DDR3 ECC Registered (RDIMM) Memory SupportRDIMM 1Gb (x8 DRAM) 2Gb (x8 DRAM)Single Rank Up

Seite 40

Chapter 5: Advanced Motherboard Setup5-11Figure 5-5. DIMM InstallationNote: Due to memory allocation to system devices, the amount of memory that rema

Seite 41

5-12SUPERSERVER 5016I-T/5016I-TF User's Manual5-7 Installing a PCI Expansion CardThe SC811T-280 chassis can accommodate one full-size PCI-Expres

Seite 42 - Removing the Heatsink

Chapter 5: Advanced Motherboard Setup5-13Figure 5-6. X8SIL/X8SIL-F Layout5-8 Motherboard Details1MAC CODEJPI2CJF1JPW1U26J8J6J5J141J13U61T-SGPIO1T-SGPI

Seite 43 - 5-6 Installing Memory

5-14SUPERSERVER 5016I-T/5016I-TF User's ManualX8SIL/X8SIL-F JumpersNumber Jumper Description Default38 JPUSB1 BP USB0/1 Wake-up Pins 1-2 (Enabled

Seite 44 - Memory Population Guidelines

Chapter 5: Advanced Motherboard Setup5-155-9 Connector Defi nitions ATX Power 24-pin ConnectorPin Defi nitions (JPW1)Pin# Defi nition Pin #

Seite 45

vPrefaceNotes

Seite 46

5-16SUPERSERVER 5016I-T/5016I-TF User's ManualHDD LEDThe HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display HDD

Seite 47 - REV:1.00

Chapter 5: Advanced Motherboard Setup5-17Fan HeadersThe X8SIL/X8SIL-F has five fan headers, all of which are 4-pin fans. However, pins 1-3 of the fan

Seite 48

5-18SUPERSERVER 5016I-T/5016I-TF User's ManualLAN1/LAN2 (Ethernet Ports)Two Ethernet ports are located on the I/O backplane. These ports accept R

Seite 49 - 5-9 Connector Defi nitions

Chapter 5: Advanced Motherboard Setup5-19NC = No ConnectionPower Supply I2C ConnectorThe Power Supply (I2C) connector is located at SMB_PS1 and is use

Seite 50

5-20SUPERSERVER 5016I-T/5016I-TF User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can

Seite 51

Chapter 5: Advanced Motherboard Setup5-21LAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the LAN1 and LAN2 Eth

Seite 52

5-22SUPERSERVER 5016I-T/5016I-TF User's Manual5-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located on the I/O backplane) have two LEDs.

Seite 53

Chapter 5: Advanced Motherboard Setup5-235-12 SATA and Floppy Drive ConnectionsSATA PortPin Defi nitions(I-SATA0 ~ I-SATA5)Pin # Defi nitio

Seite 54 - 5-10 Jumper Settings

5-24SUPERSERVER 5016I-T/5016I-TF User's ManualNotes

Seite 55

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Seite 56 - 5-11 Onboard Indicators

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Seite 57 - (I-SATA0 ~ I-SATA5)

6-2SUPERSERVER 5016I-T/5016I-TF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chassi

Seite 58

Chapter 6: Advanced Chassis Setup6-36-3 System FansTwo 10-cm blower fans provide the cooling for the SuperServer 5016I-T/5016I-TF. The chassis include

Seite 59 - Advanced Chassis Setup

6-4SUPERSERVER 5016I-T/5016I-TF User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSerial ATA Drives: Because of their hot-s

Seite 60 - 6-2 Control Panel

Chapter 6: Advanced Chassis Setup6-5Use caution when working around the SATA backplane. Do not touch the backplane with any metal objects and make sur

Seite 61 - 6-3 System Fans

6-6SUPERSERVER 5016I-T/5016I-TF User's ManualSATA Power CablesSATA power cables should be routed so that they do not block the airfl ow through th

Seite 62 - Serial ATA Drive Installation

Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe 5016I-T/5016I-TF has a single 280 watt power supply, which can operate at 100 or 240 input vol

Seite 63

6-8SUPERSERVER 5016I-T/5016I-TF User's ManualNotes

Seite 64 - DVD-ROM Drive Installation

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8SIL/X8SIL-F. The AMI ROM BIOS is stored i

Seite 65 - 6-5 Power Supply

7-2SUPERSERVER 5016I-T/5016I-TF User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the me

Seite 66

Chapter 7: BIOS7-3When you fi rst enter the AMI BIOS Setup Utility, you will enter the Main setup screen. You can always return to the Main setup scree

Seite 67 - Chapter 7

viiTable of ContentsOverheat/Fan Fail ... 3-2NIC2 ...

Seite 68 - 7-2 Main Setup

7-4SUPERSERVER 5016I-T/5016I-TF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to a

Seite 69

Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The opti

Seite 70 - XBOOT Feature

7-6SUPERSERVER 5016I-T/5016I-TF User's Manualthe components whenever needed. Select Disabled to enhance system stability. The options are Disable

Seite 71 - Processor & Clock Options

Chapter 7: BIOS7-7Intel® Turbo Boost Technology (Available if Intel® EIST technology is Enabled)This feature allows processor cores to run faster than

Seite 72

7-8SUPERSERVER 5016I-T/5016I-TF User's ManualActive State Power ManagementSelect Enabled to start Active-State Power Management for signal transa

Seite 73 - Advanced Chipset Control

Chapter 7: BIOS7-9SATA#2 Confi guration (Available if IDE is enabled under "Confi gure SATA#1 as" above)Selecting Enhanced will set SATA#2 to

Seite 74 - SATA / Floppy Confi guration

7-10SUPERSERVER 5016I-T/5016I-TF User's ManualSelect Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE d

Seite 75

Chapter 7: BIOS7-11Select UDMA4 to allow the BIOS to use Ultra DMA mode 4 . It has a data transfer rate of 100 MBs. The options are Auto, SWDMAn, MWD

Seite 76

7-12SUPERSERVER 5016I-T/5016I-TF User's ManualPCI Slots 5, 6, 7 & PCI Slot 4 OPROMUse this feature to enable or disable PCI slot Option ROMs.

Seite 77 - XPCI/PnP Confi guration

Chapter 7: BIOS7-13XRemote Access Confi guration Remote Access This allows the user to enable the Remote Access feature. The options are Dis-abled and

Seite 78

viiiPower On LED ... 5-16Chassis Intrusion ...

Seite 79 - XRemote Access Confi guration

7-14SUPERSERVER 5016I-T/5016I-TF User's ManualXHardware Health Confi gurationThis feature allows the user to monitor Hardware Health of the system

Seite 80 - Hardware Health Confi guration

Chapter 7: BIOS7-15User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.High – T

Seite 81

7-16SUPERSERVER 5016I-T/5016I-TF User's ManualCPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstat

Seite 82 - XACPI Confi guration

Chapter 7: BIOS7-17ACPI Version FeaturesThe options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanatio

Seite 83

7-18SUPERSERVER 5016I-T/5016I-TF User's ManualIP Address - Enter the IP address for this machine. This should be in decimal and in dotted quad fo

Seite 84 - XEvent Log Confi guration

Chapter 7: BIOS7-19on the system. The options are Enabled and Disabled. When enabled the following information are displayed along with their status.:

Seite 85

7-20SUPERSERVER 5016I-T/5016I-TF User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both pass-w

Seite 86 - 7-4 Security Settings

Chapter 7: BIOS7-21Use this feature to confi gure Boot Settings:XBoot Device PriorityThis feature allows the user to specify the sequence of priority f

Seite 87 - 7-5 Boot Settings

7-22SUPERSERVER 5016I-T/5016I-TF User's ManualSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Save

Seite 88 - 7-6 Exit Options

Chapter 7: BIOS7-23Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration

Seite 89

Serial ATA Drive Installation ... 6-4SATA Power Cables ...

Seite 90

7-24SUPERSERVER 5016I-T/5016I-TF User's ManualNotes

Seite 91 - POST Error Beep Codes

Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesThis section lists POST (Power On Self Test) error beep codes for the AMI BIOS. PO

Seite 92

A-2SUPERSERVER 5016I-T/5016I-TF User's ManualNotes

Seite 93 - Installing Windows

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South

Seite 94

B-2SUPERSERVER 5016I-T/5016I-TF User's ManualB-2 Installing Windows to a Non-RAID SystemInsert Microsoft's Windows OS Setup CD in the CD-RO

Seite 95 - System Specifi cations

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors One Intel® 3400 series processor in an LGA1156 socket Note:

Seite 96

C-2SUPERSERVER 5016I-T/5016I-TF User's ManualWeight Gross Weight: 30 lbs. (13.6 kg.)System Cooling Two 10-cm blower fans (FAN-0038L4

Seite 97

C-3Appendix C: System Specifi cationsNotes

Seite 98

C-4SUPERSERVER 5016I-T/5016I-TF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in l

Kommentare zu diesen Handbüchern