5-15
Chapter 5: Chassis Setup and Maintenance
Three heavy-duty fans provide the best cooling for the system. These fans circulate
air through the chassis as a means of lowering the system's internal temperature.
System fans are hot-swappable. This means that there is no need to power-down the
system when replacing a system fan. Never run the system for an extended period
of time without all of the required system fans in place and functioning properly.
5-9 System Fans
Figure 5-13: System Fan
Release Tab
Replacing a System Fan
1. If necessary, open the chassis top cover while the power is running to deter-
mine which fan has failed. (Never run the server for an extended period of
time with the chassis top cover open.)
2. Press the fan release tab to lift the failed fan from the chassis and pull it
completely from the chassis.
3. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point inward toward the
system's motherboard.
4. Check that the fan is working properly before replacing the chassis top cover.