
6-5
Chapter 6: Rack Installation
Mid-Mount Telco Rack
The SC502 supports Telco Rack installation. The SC502 chassis compact design
allows the chassis to be installed into a Telco rack without the use of rails.
Installing the Chassis into a Telco (Post Style) Rack:
To install the chassis into a Telco type rack, use two L-shaped brackets on either
side of the chassis (four total). First, determine how far follow the server will extend
out the front of the rack. Larger chassis should be positioned to balance the weight
between front and back. If a bezel is included on your chassis, remove it. Then at-
tach the two front brackets to each side of the chassis, then the two rear brackets
positioned with just enough space to accommodate the width of the Telco rack.
Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 6-2: Installing the Chassis into a Telco Rack
Kommentare zu diesen Handbüchern