®SUPERSERVER® 6028R-TR6028R-TRT SUPERUSER’S MANUAL 1.0
1-2SUPERSERVER 6028R-TR/TRT User's Manual1-2 Serverboard FeaturesThe SuperServer 6028R-TR/TRT is built around the X10DRi-/X10DRi-T, a dual pro-c
7-18SUPERSERVER 6028R-TR/TRT User's ManualsSATA RAID Option ROM/UEFI DriverSelect EFI to load the EFI driver for system boot. Select Legacy to lo
Chapter 7: BIOS7-19•ME Firmware Status #2•Current State•Error CodeAltitudeThis feature indicates the altitude of the platform this machine is locat
7-20SUPERSERVER 6028R-TR/TRT User's ManualAbove 4G Decoding (Available if the system supports 64-bit PCI decoding)Select Enabled to decode a PCI
Chapter 7: BIOS7-21Onboard LAN Option ROM TypeSelect Enabled to enable Option ROM support to boot the computer using a device installed on the slot sp
7-22SUPERSERVER 6028R-TR/TRT User's ManualDevice ModeUse this feature to congure SUART clock source settings. The options are 24MHz/1
Chapter 7: BIOS7-23is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a par
7-24SUPERSERVER 6028R-TR/TRT User's ManualSOL/COM2Console RedirectionSelect Enabled to use the SOL port for Console Redirection. The options are
Chapter 7: BIOS7-25Flow ControlUse this feature to set the ow control for Console Redirection to prevent data loss caused by buffer overow. Send a &
7-26SUPERSERVER 6028R-TR/TRT User's Manual*If the item above set to Enabled, the following items will become available for user's congurati
Chapter 7: BIOS7-27Trusted Computing (Available when a TPM device is installed and detected by the BIOS)CongurationSecurity Device SupportIf this f
1-3Chapter 1: IntroductionGraphics ControllerThe X10DRi-/X10DRi-T features an integrated Aspeed 2400 controller.1-3 Server Chassis FeaturesThe SC825T
7-28SUPERSERVER 6028R-TR/TRT User's ManualACPI Settings WHEA SupportSelect Enabled to support the Windows Hardware Error Architecture (WHEA) pla
Chapter 7: BIOS7-297-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log SettingsThis feature allows the user to co
7-30SUPERSERVER 6028R-TR/TRT User's ManualMemory Correctable Error ThresholdUse this item to enter the threshold value for correctable memory err
Chapter 7: BIOS7-317-5 IPMIUse this feature to congure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware RevisionTh
7-32SUPERSERVER 6028R-TR/TRT User's ManualWhen SEL is FullThis feature allows the user to determine what the BIOS should do when the sys-tem even
Chapter 7: BIOS7-33Gateway IP AddressThis item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i
7-34SUPERSERVER 6028R-TR/TRT User's Manual7-6 Security SettingsThis menu allows the user to congure the following security settings
Chapter 7: BIOS7-357-7 Boot SettingsUse this feature to congure Boot Settings:Boot Mode SelectUse this item to select the type of device to be used
7-36SUPERSERVER 6028R-TR/TRT User's Manual•Dual Boot Order #10•Dual Boot Order #11•Dual Boot Order #12•Dual Boot Order #13•Dual Boot Order #
Chapter 7: BIOS7-377-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard
1-4SUPERSERVER 6028R-TR/TRT User's ManualFigure 1-1. Chipset System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for
7-38SUPERSERVER 6028R-TR/TRT User's ManualRestore DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each syst
A-2SUPERSERVER 6028R-TR/TRT User's ManualNotes
B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsSingle or dual Intel® E5-2600 Series (V3) Socket R3 processors in LGA 20
B-2SUPERSERVER 6028R-TR/TRT User's ManualChassisSC825TQ-R740LPB (2U rackmount)Dimensions: (WxHxD) 16.8 x 3.5 x 25.5 in. (427 x 89 x 648 mm)Weight
B-3Appendix B: System SpecicationsElectromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
B-4SUPERSERVER 6028R-TR/TRT User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
1-6SUPERSERVER 6028R-TR/TRT User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6028
2-2SUPERSERVER 6028R-TR/TRT User's Manual•This product is for installation only in a Restricted Access Location (dedicated equipment rooms, serv
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 6028R-TR/TRT User's Manual2-4 Installing the System into a RackThis section provides information on installing the SC825 chassis
Chapter 2: Server Installation2-5Figure 2-1: Separating the Rack Rails screw the handles the outer rails for secure purpose if necessaryF.ABLECOMDATE:
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-6SUPERSERVER 6028R-TR/TRT User's ManualOuter Rack RailsOuter rails attach to the rack and hold the chassis in place. The outer rails for the SC
Chapter 2: Server Installation2-7screw the handles the outer rails for secure purpose if necessaryF.ABLECOMDATE:2008/08/14REV:2SCREWSCREWCOMPLETE12Fig
2-8SUPERSERVER 6028R-TR/TRT User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carri
SUPERSERVER 6028R-TR/TRT User's Manual3-2Note: deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was a
Chapter 3: System Interface3-312NIC1Indicates network activity on the LAN1 port when ashing.NIC2Indicates network activity on the LAN2 port when ash
SUPERSERVER 6028R-TR/TRT User's Manual3-4Notes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe
4-2SUPERSERVER 6028R-TR/TRT User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in einer S
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
4-4SUPERSERVER 6028R-TR/TRT User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to the
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 6028R-TR/TRT User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電源
4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu
4-8SUPERSERVER 6028R-TR/TRT User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and quali
4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi
4-10SUPERSERVER 6028R-TR/TRT User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Repla
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
4-12SUPERSERVER 6028R-TR/TRT User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein tr
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能
SUPERSERVER 6028R-TR/TRT User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X10DRi-/X10DRi-T ser
4-14SUPERSERVER 6028R-TR/TRT User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 6028R-TR/TRT User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met a
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 6028R-TR/TRT User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables an
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 6028R-TR/TRT User's ManualNotes
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cab
5-2SUPERSERVER 6028R-TR/TRT User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When
Chapter 5: Advanced Serverboard Setup5-35-3 I/O PortsSee Figure 5-2 below for the descriptions of the various rear I/O ports.Figure 5-1. Control Pane
NotesPrefacev
5-4SUPERSERVER 6028R-TR/TRT User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled 'Ope
Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,
5-6SUPERSERVER 6028R-TR/TRT User's ManualWarning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properl
Chapter 5: Advanced Serverboard Setup5-71. Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the sequence sho
5-8SUPERSERVER 6028R-TR/TRT User's ManualMemory SupportThe X10DRi/X10DRi-T supports up to 1 TB of DDR4-2133/1866/1600/1333 RDIMM ECC memory (or 2
Chapter 5: Advanced Serverboard Setup5-9Processor & Memory Module Population CongurationFor memory to work properly, follow the tables below for
5-10SUPERSERVER 6028R-TR/TRT User's Manual5-6 Adding PCI Add-On CardsThe 6028R-TR/TRT can accommodate six low-prole PCI add-on cards.Installing
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X10DRi/X10DRi-T Layout(not drawn to scale)5-7 Serverboard DetailsJPI2C1JPWR1JPWR2JOH1JL1JSD1JSD2
5-12SUPERSERVER 6028R-TR/TRT User's ManualX10DRi/X10DRi-T Quick ReferenceJumper Description Default SettingJBR1 BIOS Recovery Enable/Disable Pins
Chapter 5: Advanced Serverboard Setup5-13(CPU2) Slot5 PCI-Express 3.0 x8 Slot from CPU2(CPU2) Slot6 PCI-Express 3.0 x16 Slot from CPU2(T-)SGPIO1/2/3 S
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-14SUPERSERVER 6028R-TR/TRT User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset swi
Chapter 5: Advanced Serverboard Setup5-15HDD LEDThe HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show HDD activ
5-16SUPERSERVER 6028R-TR/TRT User's ManualFan HeadersThere are eight fan headers on the serverboard (Fan 1-Fan 6, Fan A, Fan B), all of which are
Chapter 5: Advanced Serverboard Setup5-17Internal SpeakerThe Internal Speaker, located at SP1, can be used to provide audible indica-tions for various
5-18SUPERSERVER 6028R-TR/TRT User's ManualStandby PowerThe Standby Power header is located at JSTBY1 on the serverboard. See the table on the
Chapter 5: Advanced Serverboard Setup5-19Universal Serial Bus (USB)Two USB 2.0 ports (USB 0/1) and two USB 2.0/3.0 ports (USB12/13) are lo-cated on th
5-20SUPERSERVER 6028R-TR/TRT User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be us
Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con
5-22SUPERSERVER 6028R-TR/TRT User's ManualI2C to PCI-E SlotsJumper SettingsJumper Setting Denition Pins 1-2 EnabledPins 2-3 DisabledI2C
Chapter 5: Advanced Serverboard Setup5-235-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each port,
viiNIC2 ... 3-3HDD ...
5-24SUPERSERVER 6028R-TR/TRT User's Manual5-11 SATA PortsSATA PortPin DenitionsPin# Denition Pin Denition1 Ground 2 TXP3 TXN
Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.
5-26SUPERSERVER 6028R-TR/TRT User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based i
Chapter 5: Advanced Serverboard Setup5-27Figure 5-7. Installing the Onboard BatteryORPlease handle used batteries carefully. Do not damage the battery
5-28SUPERSERVER 6028R-TR/TRT User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-
6-2SUPERSERVER 6028R-TR/TRT User's ManualFigure 6-1. Front and Rear Chassis ViewsSystem Reset6-2 Control PanelThe control panel (located on the
Chapter 6: Advanced Chassis Setup6-36-3 System FansThree 8-cm hot-swap fans provide the cooling for the system. It is very important that the chassis
6-4SUPERSERVER 6028R-TR/TRT User's ManualFigure 6-2. Removing System Cooling Fans6-4 Drive Bay Installation/RemovalAccessing the Drive BaysYou
Chapter 6: Advanced Chassis Setup6-5SATA Drive InstallationThese drives are mounted in carriers to simplify their installation and removal from the ch
viiiSUPERSERVER 6028R-TR/TRT User's Manual5-8 Connector Denitions ...
6-6SUPERSERVER 6028R-TR/TRT User's ManualHard Drive BackplaneThe hard drives plug into a backplane that provides power, drive ID and bus termi-na
Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 6028R-TR/TRT has a 740 watt redundant power supply consisting of two power module
6-8SUPERSERVER 6028R-TR/TRT User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRi/X10DRi-T. The ROM BIOS is stored
7-2SUPERSERVER 6028R-TR/TRT User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory
Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh
7-4SUPERSERVER 6028R-TR/TRT User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <Enter> to
Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur
7-6SUPERSERVER 6028R-TR/TRT User's ManualCPU CongurationNorth BridgeThis feature allows the user to congure the settings for the Intel North
Chapter 7: BIOS7-7The following items will be display:PCI-E Port Link StatusPCI-E Port Link MaxPCI-E Port Link SpeedPCI-E Port L0s Exit LatencyUse thi
Chapter 1 Introduction1-1 OverviewThe SuperServer 6028R-TR/TRT is a high-end server comprised of two main subsystems: the SC825TQ-R740LPB 2U chassis
7-8SUPERSERVER 6028R-TR/TRT User's ManualNo PCIe Port Active ECOUse this feature to select a workaround setting to implement the engineering-chan
Chapter 7: BIOS7-9Coherency Support (Isoch)Select Enable for the Iscoh VT-d engine to pass through ATS to enhance system performance. The options are
7-10SUPERSERVER 6028R-TR/TRT User's ManualMemory CongurationEnforce PORSelect Enable to enforce POR restrictions on DDR4 frequency and voltage
Chapter 7: BIOS7-11Rank InterleavingUse this item to select a rank memory interleaving method. The options are Auto, 1-Way, 2-Way, 4-Way, and 8-Way.A7
7-12SUPERSERVER 6028R-TR/TRT User's Manualwrite back one cache line every 16K cycles, if there is no delay caused by internal processing. By usin
Chapter 7: BIOS7-13XHCI Hand-OffThis is a work-around solution for operating systems that do not support XHCI (Ex-tensible Host Controller Interface)
7-14SUPERSERVER 6028R-TR/TRT User's ManualSATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SAT
Chapter 7: BIOS7-15Port 0 ~ Port 5 SATA Device TypeUse this item to specify if the SATA port specied by the user should be con-nected to a
7-16SUPERSERVER 6028R-TR/TRT User's ManualPort 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by the user,
Chapter 7: BIOS7-17•Software Preserve Support sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied by the user. The options are Disabl