Supermicro AS-1012G-MTF Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Server Barebones Supermicro AS-1012G-MTF herunter. Supermicro AS-1012G-MTF server barebone Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 96
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - SUPER

SUPER®SUPERSERVER 1012G-MTFUSER’S MANUALRevision 1.0

Seite 2

xSUPERSERVER 1012G-MTF User's Manual7-5 Exit Menu ...

Seite 3 - Manual Organization

Chapter 1 Introduction1-1 OverviewThe SuperServer 1012G-MTF is a short-depth server comprised of two main subsystems: the SC813MTS-350C 1U chassis and

Seite 4

1-2SUPERSERVER 1012G-MTF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 1012G-MTF lies the H8SGL-F, a single processor moth

Seite 5

1-3Chapter 1: IntroductionOther FeaturesOther onboard features that promote system health include onboard voltage monitors, a chassis intrusion header

Seite 6 - Table of Contents

1-4SUPERSERVER 1012G-MTF User's ManualFigure 1-1. AMD SR5690/SP5100 Chipset: System Block Diagram Note: This is a general block diagram. Please s

Seite 7 - Chapter 4 System Safety

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40

Seite 8

1-6SUPERSERVER 1012G-MTF User's ManualNotes

Seite 9 - Chapter 7 BIOS

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 1012G-

Seite 10

2-2SUPERSERVER 1012G-MTF User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in front of the rack to enable y

Seite 11 - Introduction

Chapter 2: Server Installation2-3Allow the hot plug SAS/SATA drives and power supply modules to cool before • touching them.Always keep the rack'

Seite 12 - 1-2 Motherboard Features

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Seite 13 - 1-3 Server Chassis Features

2-4SUPERSERVER 1012G-MTF User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServer 1012G

Seite 14 - Cooling System

Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 1012G-MTF in the rack (see Rack and Server

Seite 15 - 1-4 Contacting Supermicro

2-6SUPERSERVER 1012G-MTF User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the Server into t

Seite 16

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a Tel

Seite 17 - Server Installation

2-8SUPERSERVER 1012G-MTF User's ManualFigure 2-4. Typical Server with Top Cover Open2-5 Checking the Motherboard SetupAfter you install the 1012

Seite 18 - Warnings and Precautions!

Chapter 2: Server Installation2-9Checking the ComponentsYou may have the processor already installed into the system board. 1. The processor should ha

Seite 19 - Rack Mounting Considerations

2-10SUPERSERVER 1012G-MTF User's ManualChecking the Airfl owFollow the steps for "Accessing the Inside of the System" in Section 2-5 to

Seite 20

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SATA driv

Seite 21 - Installing the Rack Rails

3-2SUPERSERVER 1012G-MTF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTS-350C chassis has fi ve LEDs. T

Seite 22

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Seite 23

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Seite 24

3-4SUPERSERVER 1012G-MTF User's ManualNotes

Seite 25

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Seite 26

SUPERSERVER 1012G-MTF User's Manual4-2The power supply power cords must include a grounding plug and must be • plugged into grounded electrical o

Seite 27 - System Interface

Chapter 4: System Safety4-3While working on the system, do not wear loose clothing such as neckties and • unbuttoned shirt sleeves, which can come int

Seite 28 - 3-3 Control Panel LEDs

SUPERSERVER 1012G-MTF User's Manual4-4For grounding purposes, make sure your computer chassis provides excellent • conductivity between the power

Seite 29 - 3-4 Drive Carrier LEDs

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install the H8SGL-F motherboard

Seite 30

5-2SUPERSERVER 1012G-MTF User's ManualUnpackingThe motherboard is shipped in antistatic packaging to avoid electrical static discharge. When unpa

Seite 31 - System Safety

Chapter 5: Advanced Motherboard Setup5-35-3 Connecting CablesNow that the motherboard is installed, the next step is to connect the cables to the boar

Seite 32

5-4SUPERSERVER 1012G-MTF User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 bel

Seite 33 - 4-3 ESD Precautions

Chapter 5: Advanced Motherboard Setup5-55-5 Processor and Heatsink InstallationInstalling the ProcessorsBegin by removing the cover plate that 1. pro

Seite 34 - BATTERY HOLDER

SUPERSERVER 1012G-MTF User's ManualivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC813MTS-350CB chassis.

Seite 35 - Advanced Motherboard Setup

5-6SUPERSERVER 1012G-MTF User's ManualTriangleUse your thumb and your index fi nger 3. to hold the CPU. Locate and align pin 1 of the CPU socket w

Seite 36 - 5-2 Motherboard Installation

Chapter 5: Advanced Motherboard Setup5-7Installing a Passive CPU HeatsinkDo not apply any thermal grease to the heatsink or the CPU die -- the 1. requ

Seite 37 - 5-3 Connecting Cables

5-8SUPERSERVER 1012G-MTF User's Manual!CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.5-6

Seite 38 - 5-4 I/O Ports

Chapter 5: Advanced Motherboard Setup5-9Memory Population for Optimal Performance-For a Motherboard with One CPU (CPU1) Installed# DIMMS CPU Branch 0

Seite 39

5-10SUPERSERVER 1012G-MTF User's ManualSystem Device Size Physical Memory Available (4 GB Total System Memory)Firmware Hub fl ash memory (System B

Seite 40

Chapter 5: Advanced Motherboard Setup5-115-8 Motherboard DetailsFigure 5-6. H8SGL-F Motherboard Layout (not drawn to scale)Notes:Jumpers not indicated

Seite 41 - No. 2 Screw

5-12SUPERSERVER 1012G-MTF User's ManualH8SGL-F Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JCF1 Compact Fla

Seite 42 - 5-6 Installing Memory

Chapter 5: Advanced Motherboard Setup5-13Connector DescriptionCOM1/COM2 COM1 Serial Port/HeaderFAN 1-6 Chassis/CPU Fan Headers IDE#1 IDE Disk Drive Co

Seite 43

5-14SUPERSERVER 1012G-MTF User's Manual5-9 Connector Defi nitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU

Seite 44 - (4 GB Total System

Chapter 5: Advanced Motherboard Setup5-15NIC2 (LAN2) LEDThe LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display net

Seite 46 - H8SGL-F Quick Reference

5-16SUPERSERVER 1012G-MTF User's ManualUniversal Serial Bus PortsTwo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mou

Seite 47 - Connector Description

Chapter 5: Advanced Motherboard Setup5-17Wake-On-LANThe Wake-On-LAN header is designated JWOL. See the table on the right for pin defi nitions. You mus

Seite 48 - 5 through 8 +12V

5-18SUPERSERVER 1012G-MTF User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and PS/2 mouse are located next to the Back Pa

Seite 49

Chapter 5: Advanced Motherboard Setup5-19Compact Flash Card PWR ConnectorA Compact Flash Card Power Connector is located at JWF1. For the Compact Flas

Seite 50

5-20SUPERSERVER 1012G-MTF User's ManualVGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and

Seite 51

Chapter 5: Advanced Motherboard Setup5-21Watch Dog Enable/DisableJWD enables the Watch Dog function, a system monitor that takes action when a softwar

Seite 52

5-22SUPERSERVER 1012G-MTF User's Manual5-11 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On ea

Seite 53 - 5-10 Jumper Settings

Chapter 5: Advanced Motherboard Setup5-235-12 IDE and SATA Drive ConnectionsWhen connecting IDE cables, a red mark on a wire typically designates the

Seite 54

5-24SUPERSERVER 1012G-MTF User's Manual5-13 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and the SAT

Seite 55

Chapter 5: Advanced Motherboard Setup5-25Enabling SATA RAID in the BIOSBefore installing the Windows Operating System, you must change some settings i

Seite 56 - 5-11 Onboard Indicators

viSUPERSERVER 1012G-MTF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Seite 57 - (SATA0-SATA3)

5-26SUPERSERVER 1012G-MTF User's ManualFigure 5-8.Adaptec RAID Utility Program ScreenUsing the Adaptec RAID UtilityThe Adaptec® RAID Utility prog

Seite 58 - 5-13 Enabling SATA RAID

Chapter 5: Advanced Motherboard Setup5-27Figure 5-9. Driver/Tool Installation Display Screen5-14 Installing DriversThe CD that came bundled with the s

Seite 59

5-28SUPERSERVER 1012G-MTF User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote manageme

Seite 60

Chapter 5: Advanced Motherboard Setup5-29Note: Super Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.co

Seite 61 - 5-14 Installing Drivers

5-30SUPERSERVER 1012G-MTF User's ManualNotes

Seite 62 - Supero Doctor III

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan

Seite 63

6-2SUPERSERVER 1012G-MTF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chassis) must

Seite 64

Chapter 6: Advanced Chassis Setup6-36-3 System FansSix 4-cm high-performance fans provide the cooling for the SuperServer 1012G-MTF. The chassis inclu

Seite 65 - Advanced Chassis Setup

6-4SUPERSERVER 1012G-MTF User's ManualFigure 6-4. Mounting a Drive in a CarrierUse caution when working around the SATA backplane. Do not touch t

Seite 66 - 6-2 Control Panel

Chapter 6: Advanced Chassis Setup6-5Installing/Removing SAS/SATA DrivesTo remove a carrier, push the release button located beside the drive LEDs.1. S

Seite 67 - 6-3 System Fans

viiTable of Contents2-6 Checking the Drive Bay Setup ... 2-9Chapter 3 System Int

Seite 68 - SATA Drive Installation

6-6SUPERSERVER 1012G-MTF User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM dr

Seite 69 - SATA Backplane

Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 1012G-MTF has a single 350 watt power supply. This power supply has the capability

Seite 70 - DVD-ROM Drive Installation

6-8SUPERSERVER 1012G-MTF User's ManualNotes

Seite 71 - 6-5 Power Supply

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the H8SGL-F. The AMI ROM BIOS is stored in a Fl

Seite 72

7-2SUPERSERVER 1012G-MTF User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory te

Seite 73 - Chapter 7

Chapter 7: BIOS7-37-3 Advanced Settings Menu Boot FeatureQuick BootIf Enabled, this option will skip certain tests during POST to reduce the time ne

Seite 74 - 7-2 Main Menu

7-4SUPERSERVER 1012G-MTF User's ManualRestore on AC Power LossThis sets the action that occurs when an AC power loss occurs. Options include Powe

Seite 75 - 7-3 Advanced Settings Menu

Chapter 7: BIOS7-5CPU Down CoreThis option sets down core support for the CPU. Options include Disabled, 2 Cores through 10 Cores in even numbered inc

Seite 76

7-6SUPERSERVER 1012G-MTF User's Manual ECC Confi gurationECC ModeThis submenu affects the DRAM scrub rate based on its setting. Options include D

Seite 77 -  NorthBridge Confi guration

Chapter 7: BIOS7-7Legacy USB SupportSelect "Enabled" to enable the support for USB Legacy. Disable Legacy support if there are no USB device

Seite 78 -  DRAM Timing Confi guration

viiiSUPERSERVER 1012G-MTF User's Manual5-9 Connector Defi nitions ...

Seite 79 -  IDE Confi guration

7-8SUPERSERVER 1012G-MTF User's ManualPIO ModePIO (Programmable I/O) mode programs timing cycles between the IDE drive and the programmable IDE c

Seite 80

Chapter 7: BIOS7-9 PCI/PnP Confi gurationClear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug & Play O/SSelect Yes

Seite 81 -  PCI/PnP Confi guration

7-10SUPERSERVER 1012G-MTF User's ManualPrimary Video ControllerThis option specifi es the primary video controller for Onboard VGA or Other. Sup

Seite 82 -  Remote Access Confi guration

Chapter 7: BIOS7-11Flow ControlSelects the fl ow control to be used for console redirection. Options are None, Hardware and Software.Redirection After

Seite 83

7-12SUPERSERVER 1012G-MTF User's Manual ACPI Confi gurationPS2 KB/MS WakeupThis setting allows you to Enable or Disable PS2 keyboard and mouse wa

Seite 84 -  Set LAN Confi guration

Chapter 7: BIOS7-13IP Address SourceSelect the source of this machine's IP address. If Static is selected, you will need to know and enter manual

Seite 85

7-14SUPERSERVER 1012G-MTF User's Manual Event Log Confi gurationView Event Log Pressing the Enter key will open the event log. Use the "&q

Seite 86 - 7-3 Security Menu

Chapter 7: BIOS7-157-4 Boot MenuThe Boot Menu is accessible only when the "Load Onboard LAN Option ROM" setting (in the PCI/PnP Confi guratio

Seite 87 - 7-4 Boot Menu

7-16SUPERSERVER 1012G-MTF User's Manual7-5 Exit MenuSelect the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Sa

Seite 88 - 7-5 Exit Menu

Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed each time the s

Seite 89 - POST Error Beep Codes

Table of ContentsixPower LED ... 5-225-12 IDE and SATA Dr

Seite 90

A-2SUPERSERVER 1012G-MTF User's ManualNotes

Seite 91 - Installing Windows

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure RAID Settin

Seite 92

B-2SUPERSERVER 1012G-MTF User's ManualFrom the Windows XP/Windows 2003 Setup screen, press the <Enter> key. 9. The XP/2003 Setup will autom

Seite 93 - System Specifi cations

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsSingle AMD Opteron 6100 series (Socket G34 type) processorsNote: Please

Seite 94

C-2SUPERSERVER 1012G-MTF User's ManualChassisModel: SC813MTS-350C (1U Rackmount)Dimensions: (WxHxD) 17.2 x 1.7 x 19.85 in. (437 x 43 x 504 mm)Not

Seite 95 - Regulatory Compliance

C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A

Seite 96

C-4SUPERSERVER 1012G-MTF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life sup