B-2
SUPERSERVER 7047R-TXRF User's Manual
Chassis
SC747TQ-R1K28NBP (4U/Tower rackmount)
Dimensions: (WxHxD) 11.8 x 7 x 29.4 in. (452 x 178 x 746 mm)
Weight
Gross (Bare Bone): 76 lbs. (34.5 kg.)
System Cooling
Four 9.2x3.8-cm and two 3.8-cm cooling fans (fan speed controlled by IPMI)
System Input Requirements
AC Input Voltage: 100 - 240V AC auto-range
Rated Input Current: 12-8A (100-140 V); 8-6A (180-240V)
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 1280W (Part# PWS-1K28P-SQ)
Rated Output Voltages: 1000W: +12V (83A), +5Vsb (4A) / 1280W: +12V
(106.7A), +5Vsb (4A)
Operating Environment
Operating Temperature: 10º to 35º C (32º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 95% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-
3-3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate”